3m full anechoic chamber


Anechoic test chamber

Overview


The main purpose of a 3m full anechoic chamber is to perform full compliance measurements of radiated emission and immunity at 3 meter test distance. The 3m full anechoic chamber is a multi functional EMC test facility for commercial and telecommunications testing. The combination of ferrite tiles and polystyrene hybrid absorbers on the walls, floor and ceiling creates a high performance controlled electromagnetic environment that complies with international immunity and emission test standards.


Our Chamber features:

  • Full compliance emissions test site for frequency range from 30MHz to 18GHz as per CISPR 16-1-4
  • Full compliance immunity test site for frequency range of 80MHz to 6GHz as per IEC/EN 61000-4-3
  • Shielding effectiveness according to EN 50147-1 (>80dB at 10kHz)
  • Double knife edge RF shielded entrance door 1 x 2m
  • Chamber dimensions of 8 x 5 x 4.2m
  • Honeycomb ventilation (300 x 300mm / 18GHz)
  • Fiber optic controlled turn table
  • Video monitoring unit with remote controller and LCD monitor